If you have been reading about chromatogram and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Updated 2025-09-20. Numbers and descriptions here follow the published literature rather than marketing material.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
| Property | Value | Notes |
|---|---|---|
| Validation parameter | Accuracy | Closeness to a reference value. |
| Validation parameter | Precision | Repeatability or intermediate precision. |
| Validation parameter | Linearity | Proportional response across a range. |
| System suitability check | Resolution | Separation between adjacent peaks. |
| Quality control tool | Control chart | Tracks results over time for trends. |
HPLC testing is not a single fixed procedure; it is a family of separation modes. Reversed-phase, normal-phase, ion-exchange, size-exclusion, and affinity chromatography each suit different analyte properties. Reversed-phase methods dominate because they handle many neutral and moderately polar compounds. Detection can be optical, electrochemical, or mass spectrometric, and the detector dictates what information is available. Coupling with mass spectrometry increases selectivity and enables identification when standards are unavailable. The technique cannot separate every mixture without adjustment.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
The exact size of the GPCR superfamily is unknown, but at least 831 different human genes (or about 4% of the entire protein-coding genome) have been predicted to code for them from genome sequence analysis. Although numerous classification schemes have been proposed, the superfamily was classically divided into three main classes (A, B, and C) with no detectable shared sequence homology between classes. The largest class by far is class A, which accounts for nearly 85% of the GPCR genes. Of class A GPCRs, over half of these are predicted to encode olfactory receptors, while the remaining receptors are liganded by known endogenous compounds or are classified as orphan receptors. Despite the lack of sequence homology between classes, all GPCRs have a common structure and mechanism of signal transduction. The very large rhodopsin A group has been further subdivided into 19 subgroups (A1-A19). According to the classical A-F system, GPCRs can be grouped into six classes based on sequence homology and functional similarity:
Recombinant DNA technology arose as a result of advances in biology that began in the 1950s and '60s. During these decades, a tradition of merging the structural, biochemical, and informational approaches to the central problems of classical genetics became more apparent. Two main underlying concepts of this tradition were that genes consisted of DNA and that DNA encoded information that determined the processes of replication and protein synthesis. These concepts were embodied in the model of DNA produced through the combined efforts of James Watson, Francis Crick, Rosalind Franklin, and Maurice Wilkins. Further research on the Watson-Crick model yielded theoretical advances that were reflected in new capacities to manipulate DNA. One of these capacities was recombinant DNA technology.
14-3-3 proteins are a family of conserved regulatory molecules that are expressed in all eukaryotic cells. 14-3-3 proteins have the ability to bind a multitude of functionally diverse signaling proteins, including kinases, phosphatases, and transmembrane receptors. More than 200 signaling proteins have been reported as 14-3-3 ligands. Elevated amounts of 14-3-3 protein in cerebrospinal fluid are usually a sign of rapid neurodegeneration; a common indicator of Creutzfeldt–Jakob disease.
Cilengitide, a cyclic pentapeptide (RGDfV), is an investigational drug intended to block the growth of new blood vessels in tumors by interfering with the activation of integrin αVβ3. This integrin is upregulated in tumor and activated endothelial cells. This and other anti-angiogenic therapies depend on cutting off the blood supply to the tumor micro-environment, leading to hypoxia and necrosis. Cilengitide has been evaluated for the treatment of glioblastoma, but, as is the case for other anti-angiogenic therapies, has not been shown to alter progression or improve survival either alone or in combination with standard treatments. CEND-1, also known as iRGD, is a cyclic peptide that homes to tumors via binding to integrin alpha V receptors. It also binds and activates neuropilin-1, leading to a temporary opening of the tumor and an enhanced delivery of anti-cancer agents into the tumor tissue. It is currently being tested in clinical trials in solid tumor patients.
Biopolymers are polymers produced by living organisms. Cellulose and starch, proteins and peptides, and DNA and RNA are all examples of biopolymers, in which the monomeric units, respectively, are sugars, amino acids, and nucleotides. Cellulose is both the most common biopolymer and the most common organic compound on Earth. About 33% of all plant matter is cellulose. On a similar manner, silk (a proteinaceous biopolymer) has garnered tremendous research interest across various domains, including tissue engineering, regenerative medicine, microfluidics, and drug delivery. Bionics Hydrogel Polymeric surface Surface modification of biomaterials with proteins Synthetic biodegradable polymer List of biomaterials Oxygen generating biomaterial Journal of Biomaterials Applications CREB – Biomedical Engineering Research Centre Archived 2021-05-07 at the Wayback Machine Department of Biomaterials at the Max Planck Institute of Colloids and Interfaces in Potsdam-Golm, Germany Open Innovation Campus for Biomaterials Archived 2009-04-19 at the Wayback Machine
Sources: en.wikipedia.org
After translation, the AGP protein backbones are highly decorated with complex carbohydrates, primarily type II AG polysaccharides. The biosynthesis of the mature AGP involves cleavage of the signal peptide at the N-terminus, hydroxylation on the P residues and subsequent glycosylation and in many cases addition of a GPI-anchor. Glycosylation of the AGP backbone is suggested to initiate in the ERTooltip endoplasmic reticulum with the addition of first Gal by O-galactosyltransferase, which is predominantly located in ER fractions. Chain extension then occurs primarily in the GA. For those AGPs that include a GPI anchor, addition occurs while co-translationally migrating into the ER.
Afucosylated antibodies are intensely used in the field of advanced medicine, also due to their high ADCC (antibody-dependent cellular cytotoxicity). This makes them effective in binding to specific targets while minimizing damage to surrounding tissue. Some of the fields in which afucosylated antibodies are used or considered for application are: cancer immunotherapy autoimmune diseases Infectious diseases Furthermore, afucosylated antibodies are used as diagnostic tools and play a role in the development of personalized medications.
Aleksandar Zega (29 May 1860 – 29 March 1928) was a Serbian chemist. He held professional positions in the Government, Municipal and Customs Laboratories, and made a number of applied and theoretical contributions. He dealt with analytical and organic chemistry, specifically the analysis of mineral waters and foodstuffs. He studied and worked in Switzerland, however he wrote and published most of his works during his work and stay in Serbia. He was a contemporary of Milorad Z. Jovičić (1868–1937) and Wladimir Brunetti.
The source of ADP-ribose for most enzymes that perform this modification is the redox cofactor NAD+. In this transfer reaction, the N-glycosidic bond of NAD+ that bridges the ADP-ribose molecule and the nicotinamide group is cleaved, followed by nucleophilic attack by the target amino acid side chain. (ADP-ribosyl)transferases can perform two types of modifications: mono(ADP-ribosyl)ation and poly(ADP-ribosyl)ation.
AlphaFold has been used to predict structures of proteins of SARS-CoV-2, the causative agent of COVID-19. The structures of these proteins were pending experimental detection in early 2020. Results were reviewed by scientists at the Francis Crick Institute in the United Kingdom before being released to the broader research community. The team also confirmed accurate prediction against the experimentally determined SARS-CoV-2 spike protein that was shared in the Protein Data Bank, an international open-access database, before releasing the computationally determined structures of the under-studied protein molecules. The team acknowledged that although these protein structures might not be the subject of ongoing therapeutical research efforts, they will add to the community's understanding of the SARS-CoV-2 virus. Specifically, AlphaFold 2's prediction of the structure of the ORF3a protein was very similar to the structure determined by researchers at University of California, Berkeley using cryo-electron microscopy. This specific protein is believed to assist the virus in breaking out of the host cell once it replicates. This protein is also believed to play a role in triggering the inflammatory response to the infection.
Sources: en.wikipedia.org
The Society recognizes achievements and promotes academic research through four annual awards. The Biemann Medal and the John B. Fenn Award for a Distinguished Contribution in Mass Spectrometry both are awarded in recognition of singular achievements or contributions in fundamental or applied mass spectrometry, with the Biemann Medal being focused on individuals who are early in their careers. The Ronald A. Hites Award is awarded for outstanding original research demonstrated in papers published in the Journal of the American Society for Mass Spectrometry. The Research Awards are given to young scientists in mass spectrometry, based on the evaluation of their proposed research. The Fellows of ASMS are awarded to individuals in recognition for their scientific contribution to mass spectrometry and for their contribution to the ASMS community. Journal of the American Society for Mass Spectrometry Measuring Mass: From Positive Rays to Proteins The past presidents of ASMS are:
Early experiments resembling activity-based profiling were conducted in the 1970s, when small molecules were used to study the mechanism of action of the serine-modifying antibiotic penicillin. The modern era of ABPP began in the 1990s with the development of ABPs compatible with proteomic workflows, and the first applications of ABPP were reported during this decade in studies of proteases. In 1999, the Cravatt lab formally introduced the term "activity-based protein profiling," establishing a framework for systematic functional proteomics. Subsequent work by Ben Cravatt at The Scripps Research Institute, Matthew Bogyo at Stanford University, and Herman S. Overkleeft at Leiden University helped define the field through the design of probes targeting serine hydrolases, cysteine proteases, oxidoreductases, human cytochrome P450s and other enzyme families. Since its inception, ABPP has expanded rapidly, with bibliometric analyses documenting exponential growth in publications and widespread adoption across North America, Europe, and Asia. Advances in mass spectrometry and protein separation technologies further accelerated the integration of ABPP into proteomic research, enabling the characterization of enzyme activity on a global scale and establishing ABPP as a cornerstone of functional proteomics.
The museum is located in a small two-storey building where laboratory of physics (on the first floor) and chemical laboratory (on the second floor) was designed. It was the first chemical laboratory of Kazan University. The first professor was N.N. Zinin, who studied abroad and learned new method of teaching chemistry and began to apply it in Kazan University. This method combined practical and lecture classes that is still familiar to students. There are no usual stalls and stands in the museum. It is a memorial laboratory of the 19th century which includes Butlerov's lecture room, a library, the laboratory itself, a hall for exhibiting chemical preparations and laboratory equipment of 19–20th centuries, and the study of the head of the laboratory (Butlerov's study). Nowadays in the main hall of the museum lectures and seminars and defence of master's and doctoral theses are conducted. In the side rooms you may observe modern laboratories.
Other automotive engineers include those listed below: Aerodynamics engineers will often give guidance to the styling studio so that the shapes they design are aerodynamic, as well as attractive. Body engineers will also let the studio know if it is feasible to make the panels for their designs. Change control engineers make sure that all of the design and manufacturing changes that occur are organized, managed and implemented... NVH engineers perform sound and vibration testing to prevent loud cabin noises, detectable vibrations, and/or improve the sound quality while the vehicle is on the road.
Cytochrome-b5 reductase is a NADH-dependent enzyme that converts ferricytochrome from a Fe3+ form to a Fe2+ form. It contains FAD and catalyzes the reaction: In its b5-reducing capacity, this enzyme is involved in desaturation and elongation of fatty acids, cholesterol biosynthesis, and drug metabolism. This enzyme can also reduce methemoglobin to normal hemoglobin, gaining it the inaccurate synonym methemoglobin reductase. Isoforms expressed in erythrocytes (CYB5R1, CYB5R3) perform this function in vivo. Ferricyanide is another substrate in vitro.
Sources: en.wikipedia.org
Method validation is the documented process of showing that an HPLC procedure produces reliable results for a defined purpose. It examines parameters such as accuracy, precision, specificity, linearity, and robustness. Regulators and quality systems often require validation before routine use.
System suitability is a set of checks run on the chromatographic system before sample analysis. It confirms that resolution, peak shape, retention time, and response meet predefined limits. Failure can invalidate the run and trigger corrective action.
Blank injections reveal peaks or baseline disturbances that come from solvents, reagents, or the instrument rather than the sample. They help distinguish contamination from actual analyte signals. Comparing blanks with sample runs supports accurate interpretation.
HPLC testing separates and quantifies components in a liquid sample. It is used to check identity, purity, concentration, or stability. The technique works best for compounds that dissolve and are not easily vaporized.